  Datasheet File OCR Text:
  product datasheet characteristics GV3P40 motor circuit breaker gv3 poles - 40 a - everlink btr screw connectors - thermomagnetic trip unit ? main range of product gv3p device short name thermal magnetic circuit breaker product or component type thermal magnetic circuit breaker circuit breaker application motor protection poles description 3p network type ac control type rotary knob motor power kw 22 kw at 500 v ac 50/60 hz 37 kw at 690 v ac 50/60 hz 18.5 kw at 400...415 v ac 50/60 hz trip unit technology thermal - magnetic magnetic tripping current 560 a suitability for isolation yes conforming to iec 60947 - 1 7 - 1 - 6 utilisation category ac - 3 conforming to iec 60947 - 4 - 1 category a conforming to iec 60947 - 2 connections - terminals power circuit: everlink btr screw connectors 2 cable 1...25 mm 2 - cable stiffness: solid power circuit: everlink btr screw connectors 2 cable 1...25 mm 2 - cable stiffness: flexible - without cable end power circuit: everlink btr screw connectors 1 cable 1...35 mm 2 - cable stiffness: flexible - without cable end power circuit: everlink btr screw connectors 2 cable 1...25 mm 2 - cable stiffness: flexible - with cable end power circuit: everlink btr screw connectors 1 cable 1...35 mm 2 - cable stiffness: flexible - with cable end power circuit: everlink btr screw connectors 2 cable 1...35 mm 2 - cable stiffness: solid complementary network frequency 50/60 hz mounting mode fixed mounting support plate rail mounting position horizontal vertical [in] rated current 40 a thermal protection adjustment range 30...40 a conforming to iec 60947 - 4 - 1 phase failure sensitivity yes conforming to iec 60947 - 4 - 1 7 - 2 - 1 - 5 - 2 [ue] rated operational voltage 600 v ac 50/60 hz conforming to csa c22 - 2 no 14 600 v ac 50/60 hz conforming to ul 508 690 v ac 50/60 hz conforming to iec 60947 - 2 [ui] rated insulation voltage 690 v conforming to iec 60947 - 2 [ith] conventional free air thermal current 40 a conforming to iec 60947 - 4 - 1 network frequency 50/60 hz conforming to csa 50/60 hz conforming to iec 60947 - 4 - 1 50/60 hz conforming to ul [uimp] rated impulse withstand voltage 6 kv conforming to iec 60947 - 2 power dissipation per pole 8 w mechanical durability 50000 cycles electrical durability 50000 cycles on ac - 3 at 440 v in the?information?provided?in?this?documentation?contains?general?descriptions?and/or?technical?characteristics?of?the?performance?of?the?products?contained?herein. this?documentation?is?not?intended?as?a?substitute?for?and?is?not?to?be?used?for?determining?suitability?or?reliability?of?these?products?for?specific?user?applications. it?is?the?duty?of?any?such?user?or?integrator?to?perform?the?appropriate?and?complete?risk?analysis,?evaluation?and?testing?of?the?products?with?respect?to?the?relevant?specific?application?or?use?thereof. neither?schneider?electric?industries?sas?nor?any?of?its?affiliates?or?subsidiaries?shall?be?responsible?or?liable?for?misuse?of?the?information?contained?herein. 1 / 2
maximum number of switchings 25 cyc/h rated duty continuous conforming to iec 60947 - 4 - 1 type of connector everlink btr screw connectors tightening torque 5 n.m - on everlink btr screw connectors - cable 25 mm 2 8 n.m - on everlink btr screw connectors - cable 35 mm 2 breaking capacity icu 10 ka at 500 v ac 50/60 hz conforming to iec 60947 - 2 icu 100 ka at 400...415 v ac 50/60 hz conforming to iec 60947 - 2 icu 5 ka at 690 v ac 50/60 hz conforming to iec 60947 - 2 icu 50 ka at 230...240 v ac 50/60 hz conforming to iec 60947 - 2 icu 50 ka at 440 v ac 50/60 hz conforming to iec 60947 - 2 [ics] rated service short - circuit breaking capacity 100 % at 230...240 v ac 50/60 hz conforming to iec 60947 - 2 50 % at 400...415 v ac 50/60 hz conforming to iec 60947 - 2 50 % at 440 v ac 50/60 hz conforming to iec 60947 - 2 50 % at 500 v ac 50/60 hz conforming to iec 60947 - 2 60 % at 690 v ac 50/60 hz conforming to iec 60947 - 2 height 132 mm width 55 mm depth 136 mm product weight 1.1 kg environment standards csa c22 - 2 no 14 - 05 type e en 60947 - 1 en 60947 - 2 iec 60947 - 1 iec 60947 - 2 ul 508 type e product certifications atex ccc csa gost ul protective treatment th ip degree of protection ip20 open mounted conforming to iec 60529 shock resistance 15 gn (on) and 30 gn (off) 11 ms conforming to iec 60068 - 2 - 27 vibration resistance 4 gn 5...300 hz conforming to iec 60068 - 2 - 6 ambient air temperature for operation - 20...60 c open mounted - 20...40 c in enclosure ambient air temperature for storage - 40...80 c fire resistance 960 c conforming to iec 60695 - 2 - 1 operating altitude <= 3000 m resistance to mechanical impact 10 j in enclosure 2 / 2


▲Up To Search▲   

 
Price & Availability of GV3P40

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X